Best-in-class PSA performance
Technical specifications for PPNG 6-90 HE
Options
• A host of protective
features ensure a long
lifetime of the machine
and the CMS.
• To protect your production,
the minimum purity setting
blows off nitrogen if your
selected purity is not reached
• Zirconia sensors provide
reliable purity measurement
• Self-protective monitoring of the feed air quality
• Feed-air blow-off in case of off-spec conditions
• Nitrogen flow, purity and pressure measurement
and control
• Automatic start-up
• Optional 24/7 ICONS remote monitoring of flow,
pressure, purity and all other key data in real time
• Our innovative PSA
cycle and high-quality
CMS deliver best-in
class efficiency to keep
your energy costs and
emissions low.
Outlet dewpoint sensor
Monitors the outlet nitrogen pressure
dewpoint for critical applications.
Specifications Variant
Product
Purity
Units PPNG
6 HE
PPNG
7 HE
PPNG
9 HE
PPNG
12 HE
PPNG
15 HE
PPNG
18 HE
PPNG
22 HE
PPNG
28 HE
PPNG
30 HE
PPNG
37 HE
PPNG
41 HE
PPNG
50 HE
PPNG
65 HE
PPNG
75 HE
PPNG
90 HE
Nominal free
nitrogen
delivery (1)
PCT(%) 95%
Nm³/
hr
18.2 23.4 28.7 36.4 46.9 57.3 70.3 86.0 93.8 114.7 128.9 157.7 184.8 211.4 264.3
99.5% 8.1 10.4 12.7 16.2 20.8 25.5 31.3 38.2 41.7 51.0 57.5 70.3 90.2 102.1 127.7
PPM 99.999% 1.9 2.5 3.0 3.8 4.9 6.0 8.0 9.7 10.6 13.0 15.9 19.5 26.3 29.8 37.2
Pressure dewpoint outlet °C/°F-40-40-40-40-40-40-40-40-40-40-40-40-40-40-40
Length mm 775 775 775 775 775 775 1400 1400 1400 1400 1400 1400 1421 1421 1421
inch 31 31 31 31 31 31 55 55 55 55 55 55 56 56 56
Width mm 840 840 840 840 840 840 840 840 840 840 970 970 970 970 970
inch 33 33 33 33 33 33 33 33 33 33 38 38 38 38 38
Height mm 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015
inch 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79
Mass kg 266 279 292 326 352 379 608 648 681 734 764 1039 1140 1140 1560
lbs 586 615 644 719 776 836 1340 1429 1501 1618 1684 2291 2513 2513 3439
Inlet connections PCT G/NPT DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25
Outlet connections PCT G/NPT DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25
Inlet connections PPM G/NPT DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN32 DN32 DN32
Outlet connections PPM G/NPT DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN15 DN15 DN15
(1) Flow is measured at reference conditions: 1 bara and 20°C at operating pressure of 7 barg, inlet temperature 20°C/68°F & air inlet quality of ISO 8573-1:2010 class 1-4-1
External room oxygen monitor
Measures the oxygen level in a room
to ensure safety.
Low ambient temperature version
Allows the generator to run in
temperatures down to -10°C/14°F