CFM and SCFM are two common flow rate units used in industrial equipment, especially air compressors, PSA nitrogen generators, and oxygen generators.
CFM = Cubic Feet per Minute
CFM measures the volume of gas or air flowing per minute.
C = Cubic
F = Feet
M = Minute
It indicates how much air or gas an air compressor or nitrogen generator can deliver per minute.
For example:
An air compressor rated at 100 CFM delivers a nominal airflow of 100 cubic feet per minute under its specified measurement conditions.
SCFM = Standard Cubic Feet per Minute
SCFM measures gas flow converted to a set of standard reference conditions for temperature, pressure, and sometimes humidity.
It is commonly used to compare the airflow capacity of different air compressors and gas generators on a consistent basis.
The exact standard conditions can vary by manufacturer and industry. Always check the specified reference temperature and pressure.
Comparison |
CFM |
SCFM |
|---|---|---|
Full name |
Cubic Feet per Minute |
Standard Cubic Feet per Minute |
Meaning |
Actual volumetric flow rate |
Flow rate referenced to standard conditions |
Conditions |
Actual operating conditions |
Defined standard conditions |
Application |
Airflow measurement |
Equipment capacity comparison |
Accuracy |
Depends on actual conditions |
More suitable for standardized comparison |
Key difference:
CFM describes the actual volume of gas flowing per minute at the measurement conditions.
SCFM describes the equivalent volume at specified standard conditions.
The conversion depends on temperature, pressure, humidity, and the standard conditions used.
For dry air, an approximate relationship is:
Where:
ACFM = Actual Cubic Feet per Minute
P = Absolute pressure
T = Absolute temperature (Rankine or Kelvin)
Remember: Use absolute pressure and absolute temperature, not gauge pressure or Celsius directly.
Unit |
Conversion |
|---|---|
1 CFM |
0.0283168 m³/min |
1 CFM |
1.699 m³/h |
1 SCFM |
1.699 standard m³/h |
1 Nm³/h |
0.589 SCFM* |
*Approximate, assuming compatible standard reference conditions.
For PSA nitrogen generator systems, CFM and SCFM are important when selecting the air compressor.
For example:
Equipment |
Typical flow specification |
|---|---|
Air compressor |
100 SCFM |
Air receiver tank |
Specified in gallons or liters |
Air purification system |
100 SCFM |
PSA nitrogen generator |
Nitrogen output in Nm³/h or SCFM |
Important: The air compressor's available airflow must meet the nitrogen generator's compressed-air consumption, not just its nitrogen output. The required air-to-nitrogen ratio depends on nitrogen purity, pressure, and system efficiency.
My recommendation: When selecting an air compressor for a PSA Nitrogen Generator, pay attention to SCFM or FAD (Free Air Delivery), rather than comparing CFM figures without checking their reference conditions.