1. What is CFM?

CFM = Cubic Feet per Minute

CFM measures the volume of gas or air flowing per minute.

  • C = Cubic

  • F = Feet

  • M = Minute

It indicates how much air or gas an air compressor or nitrogen generator can deliver per minute.

For example:

An air compressor rated at 100 CFM delivers a nominal airflow of 100 cubic feet per minute under its specified measurement conditions.

2. What is SCFM?

SCFM = Standard Cubic Feet per Minute

SCFM measures gas flow converted to a set of standard reference conditions for temperature, pressure, and sometimes humidity.

It is commonly used to compare the airflow capacity of different air compressors and gas generators on a consistent basis.

The exact standard conditions can vary by manufacturer and industry. Always check the specified reference temperature and pressure.

3. Difference Between CFM and SCFM

Comparison

CFM

SCFM

Full name

Cubic Feet per Minute

Standard Cubic Feet per Minute

Meaning

Actual volumetric flow rate

Flow rate referenced to standard conditions

Conditions

Actual operating conditions

Defined standard conditions

Application

Airflow measurement

Equipment capacity comparison

Accuracy

Depends on actual conditions

More suitable for standardized comparison

Key difference:

  • CFM describes the actual volume of gas flowing per minute at the measurement conditions.

  • SCFM describes the equivalent volume at specified standard conditions.

4. CFM and SCFM Conversion

The conversion depends on temperature, pressure, humidity, and the standard conditions used.

For dry air, an approximate relationship is:

\[ SCFM=ACFM\times\frac{P_{actual}}{P_{standard}}\times\frac{T_{standard}}{T_{actual}} \]

Where:

  • ACFM = Actual Cubic Feet per Minute

  • P = Absolute pressure

  • T = Absolute temperature (Rankine or Kelvin)

Remember: Use absolute pressure and absolute temperature, not gauge pressure or Celsius directly.

5. Conversion to Other Flow Units

Unit

Conversion

1 CFM

0.0283168 m³/min

1 CFM

1.699 m³/h

1 SCFM

1.699 standard m³/h

1 Nm³/h

0.589 SCFM*

*Approximate, assuming compatible standard reference conditions.

6. Application in Nitrogen Generators

For PSA nitrogen generator systems, CFM and SCFM are important when selecting the air compressor.

For example:

Equipment

Typical flow specification

Air compressor

100 SCFM

Air receiver tank

Specified in gallons or liters

Air purification system

100 SCFM

PSA nitrogen generator

Nitrogen output in Nm³/h or SCFM

Important: The air compressor's available airflow must meet the nitrogen generator's compressed-air consumption, not just its nitrogen output. The required air-to-nitrogen ratio depends on nitrogen purity, pressure, and system efficiency.

My recommendation: When selecting an air compressor for a PSA Nitrogen Generator, pay attention to SCFM or FAD (Free Air Delivery), rather than comparing CFM figures without checking their reference conditions.